Three Phase Electrical Actuator - Rotary | ATQ Series | CairindiaVietnam | Lappro

“Cair” offers three phase Quarter turn electrical actuator for valves and engineering use.
Nhà sản xuất: CAIR euromatiic
0
Enclosure
Standard enclosure to water jet proof will water tight proof IP 67.NEMA 4&6
   
Motor
Squirrel cage motor is of encapsulated type, on high stall torque and low inherent force for seating & unseating of valves. All motors are integrated with build-in thermal protection.
   
Terminal Connection & Wiring
Terminal connections are of "WAGO" push on type, making wiring connection very easy & without fuss. Electrical wiring circuit is standardized for single & three phase voltage. Addition termination is available on request.
   
Internal Components Arrangement
Internal mechanical and electrical components are design in modular mounting arrangement, and can be easily remove for maintenance purposes. Additional optional accessories are also possible.
   
Limit Switches
A pair of limit switches are activated by means of simple, reliable & adjustable cam plates, mounted directly onto, and driven by center column. The unique cam plate design does not allow over travel of limit switches.
   
Torque Switches
Electric actuators on 100 N • m and above, are install with torque switches for over-load protection.
   
Heater
For prevention of condensation due to weather& temperature changes, an d also keeps internal components clean & dry, a 20 Walt space heater is provided inside all the electric actuators.
   
Self Locking Mechanism
Because of the worm gear design system, all the electric actuators are self-locking.
   
Handwheel
Correct size of handwheel on the electric actuator ensure adequate strength for safe and efficient emergency operation.
   
Manual Over-Ride
Engage by pulling the lever & turning the handwheel. Lever is auto declutch when power supply is switch on, and hand wheel does not turn as extra safety feature.
   
Visual Position Indicator
The visual position indicator is directly mounted onto the center drive column to provide the visual position of the valve.
   
End Stoppers
1 each for open & close position (adjustable), are for over travel protection.
   
Potentiometer-Otional
Is available on request, is to provide & transmit remote indication of valve position.
   
Mounting & Adaptation
Bottom flange mounting dimension conform to ISO 5211. Aadaptor drive bushing is provided for every electric actuator. Is removable and for machining to suite valve stem size.
   
 
 
 
 
 
 
 
 
 
 
 
 
 
Performance
 
Type Max output Torque Operating Time 60/50 Hz Max Stem Dia. Motor 30 Min. Class F Rated Current (mA) Number Of Handle Turn Weight (Kg)
1 Phase 3 Phase
Kg • m 90 Deg. mm W 110V 220V 380V 440V
ATQ03* 3 14/17 14 10 650 300 N/A N/A 8.5 6
ATQ04* 4 14/17 14 10 650 300 N/A N/A 8.5 6
ATQ06* 6 14/17 22 15 1250 400 N/A N/A 8.5 9
ATQ09* 9 14/17 22 25 1500 550 190 400 8.5 10
ATQ15 15 17/20 22 40 2000 900 280 400 10 12
ATQ19 19 17/20 22 40 2000 900 280 420 10 13
ATQ28 28 22/26 32 40 2000 900 280 450 12.75 17
ATQ38 38 22/26 32 60 2700 1250 400 450 12.75 18
ATQ50 50 22/26 32 90 3300 1600 600 450 12.75 19
ATQ60 60 24/29 42 120 5000 2400 800 500 14.5 22
ATQ80 80 24/29 42 180 5800 2800 1200 850 14.5 23
ATQ100 100 24/29 42 200 8000 3000 1300 900 14.5 25
ATQ150 150 25/29 50 180 5800 2800 1200 850 45 33
ATQ200 200 25/29 50 200 8000 3000 1300 900 45 35
ATQ250 250 25/29 50 200 8000 3000 1300 900 45 35
  * Without torque switches
 
Standard Specifications
Housing & Cover Aluminium, Anodized
Enclosure Watertight IP67, Nema 4 and 6
Ambient Temp -30°C~+70°C
Power Supply (60Hz/50Hz) 110/220VAC, 1 Phase 
380/440 VAC, 3 Phase
Control Power 110/220 VAC, 1 Phase, 60/50Hz
Torque Switches 2 X SPDT for ATQ15 and above
Limit Switches 2XSPDT 15A
Stall Protection Built-in Thermal Protection
Travel Angle 90°±5°
Indicator Continuous Position Indicator
Manual Override HAND/AUTO Declutching Mechanism
Self Locking Provide by means of Worm Gearing
End Stopper External Adjustable Screws
Space Heater 20W for Anti-Condensation
Conduit Entries Two G3/4"
Lubrication MoS2 Lithium Base Grease
Materials Steel, Aluminium Alloy, Al Bronze
External Coating Dry Power, Epoxy-Polyester Munsell No.FJ-002
Optional Items
ALS Additional 2 X SPOT Auxiliary Limit Switches
EXT Travel Angle 120°, 135°, 180°, 270°
LCB Local Control Box (1)Local/Remote Selector Switch (2)Open/Stop/Close Selector Switch
POT Potentiometer 1k Ohm
CPT Current Position Transmitter Output: 4-20mA DC
PCM Proportional Control Module Input signal: 4-20mA, 1-5V DC Output signal: 4-20mA DC
EXP Explosion & Water Proof Enclosure Exd II BT4 IP67
 
 
Type ATQ03 ATQ04 ATQ06 ATQ09 ATQ15 ATQ19 ATQ28 ATQ38 ATQ50 ATQ60 ATQ80 ATQ100
Flange ISO5211 F05 F05 F07 F07 F07 F07 F10 F10 F10 F10 F12 F10 F12 F10 F12
F07 F07 F10 F10 F12 F12 F12 F14 F14 F14
C 50 50 70 70 102 102 102 102 102 125 125 125
A M6 M6 M8 M8 M10 M10 M10 M10 M10 M12 M12 M12
B 10 10 14 14 14 14 17 17 17 19 19 19
D (Max) 14 14 22 22 22 22 32 32 32 42 42 42
E 40 40 55 55 57 57 75 75 75 85 85 85
F 25 25 35 35 35 35 42 42 42 50 50 50
G 5 5 5 5 5 5 5 5 5 5 5 5
H 60 60 60 60 64 64 70 70 70 78 78 78
I 133 133 133 133 154 154 174 174 174 191 191 191
J 196 196 196 196 199 199 228 228 228 264 264 264
L 102 102 102 102 125 125 145 145 145 175 175 175
O 200 200 200 200 250 250 350 350 350 350 350 350
T 75 75 75 75 85 85 100 100 100 115 115 115
X 241 241 241 241 272 272 290 290 290 331 331 331
Y 208 208 208 208 239 239 274 274 274 306 306 306
Z 256 256 256 256 263 263 298 298 298 342 342 342
P 72 72 72 72 72 72 72 72 72 72 72 72
q 166 166 166 166 187 187 192 192 192 209 209 209
U 170 170 170 170 170 170 170 170 170 170 170 170
 
Type ATQ150 ATQ200 ATQ250
Flange F16 F16 F16
ISO5211 F14 F14 F14
C 160 160 160
A M20 M20 M20
B 30 30 30
D (Max) 50 50 50
E 95 95 95
F 60 60 60
G 4 4 4
H 241 241 241
I 191 191 191
J 264 264 264
L 210 210 210
O 350 350 350
T 132 132 132
X 357 357 357
Y 323 323 323
Z 505 505 505
   
Application
 