 (approx. 20 % / 40 % / 60 % / 80 % RH increasing and decreasing;  measurement point Temperature: approx. +23 °C) 
 
 | 
Price info
 
   | 
 
 Product-ID: 602543 | 
    
 | 
 
 
  
 | 
 
 
 | 
 
  | 
   Product Information
   Instruction Manual | 
GFTB 200 SET 
Measurement set GFTB200 incl. infrared thermometer GIM 530 MS and case GKK 3000 
 
 
- Very easy locating of heat and cold bridges
 
- Laser sighting to aim at the measurement object
 
- Audible warning at dew point undershooting
 
- Fast detection of problematic areas tending to mold infestation
 
  
 
Measuring ranges:
  
  
| 
 Temperature: 
 | 
 -25.0°C ... +70.0 °C 
 | 
 
| 
 Air humidity: 
 | 
 0.0 ... 100.0 % r.F.  (recommended range: 11 ... 90 % RH) 
 | 
 
| 
 Air pressure: 
 | 
 10.0 ... 1100.0 mbar 
 | 
 
| 
 Dew point temperature Td:  
 | 
-40,0 ... 70,0 °C | 
 
| 
 Wet bulb temperature Twb:  
 | 
-27,0 ... 70,0 °C | 
 
| 
 Moisture content x: 
 | 
0,0 ... 280,0 g/kg | 
 
| 
 Absolute humidity d:  
 | 
0,0 ... 200,0 g/m³ | 
 
 
  
 
 
- 
  
Accuracy: 
  
| 
 Temperature: 
 | 
 ±0,5 % v.MW. ±0,1°C (Pt1000 1/3 DIN B) 
 | 
 
| 
 Air humidity: 
 | 
 ±2,5 % r.F. (at range 11 bis 90%) 
 | 
 
| 
 Air pressure: 
 | 
 ±1,5 mbar (750...1100 mbar) 
 | 
 
 
  
  
  
| 
 Response time:   
 | 
T90=10sec. | 
 
| 
 Display: 
 | 
 4½ -digit, approx. 11 mm high LCD-display with additional displays 
 | 
 
| 
 Power supply:   
 | 
 9V-Batterie Typ IEC 6F22 
 | 
 
| 
 Current consumption: 
 | 
 max. 20 ?A at 1 meas. / 60 s (mode SLOW) approx. 70 ?A at 1 meas. / 1 s (mode FAST) 
 | 
 
 
  
  Technical Details: GIM 530 MS Measuring range:   -32C ... +530 °C (-20 °F ... +980 °F) Resolution:   0,1 °C (0,1 °F) Response Time (t95):   0,3 sec. Accuracy   +/- 1% or +/- 1 °C (highest value should be valid) Emission rate:   0,100 ... 1,000, adjustable Optical resolution D/S:   20:1 (Measuring Distance : Measuring Zone) Dimensions, weight:   190 x 38 x 45 mm, 150 g
  Scope of supply:   Device with battery, operating manual, device bag made of nylon
  
 
 
 | 
Price info
 
   | 
 
 Product-ID: 600163 | 
    
 | 
 
 
  
 | 
 
 
 | 
 
  | 
   Product Information
   Instruction Manual | 
GFTB 200
Hygro-/Thermo-/Barometer 
Feature: 
- air humidity, temperature and air pressure measurement
 
- additional display for further parameters, e.g. dew point
 
- temperature and absolute humidity
 
- alarm function with integrated buzzer
 
- min / max value memory
 
- very low power consumption (> 6500 operating hours)
 
- PC interface
 
 
Applications: 
- mobile weather station
 
- housing space, indoor swimming pools
 
- offi ces and production rooms, laboratories, storage rooms
 
- museums, gallery, churches
 
- Cooling and climate technology
 
- construction, building physics, loss assessment
 
 
Measuring ranges: 
  
| 
 Temperature: 
 | 
 -25.0°C ... +70.0 °C 
 | 
 
| 
 Air humidity: 
 | 
 0.0 ... 100.0 % r.F.  (recommended range: 11 ... 90 % RH) 
 | 
 
| 
 Air pressure: 
 | 
 10.0 ... 1100.0 mbar 
 | 
 
| 
 Dew point temperature Td:  
 | 
-40,0 ... 70,0 °C | 
 
| 
 Wet bulb temperature Twb:  
 | 
-27,0 ... 70,0 °C | 
 
| 
 Moisture content x: 
 | 
0,0 ... 280,0 g/kg | 
 
| 
 Absolute humidity d:  
 | 
0,0 ... 200,0 g/m³ | 
 
 
 
  
Accuracy: 
  
| 
 Temperature: 
 | 
 ±0,5 % v.MW. ±0,1°C (Pt1000 1/3 DIN B) 
 | 
 
| 
 Air humidity: 
 | 
 ±2,5 % r.F. (at range 11 bis 90%) 
 | 
 
| 
 Air pressure: 
 | 
 ±1,5 mbar (750...1100 mbar) 
 | 
 
 
  
  
  
| 
 Response time:   
 | 
T90=10sec. | 
 
| 
 Display: 
 | 
 4½ -digit, approx. 11 mm high LCD-display with additional displays 
 | 
 
| 
 Power supply:   
 | 
 9V-Batterie Typ IEC 6F22 
 | 
 
| 
 Current consumption: 
 | 
 max. 20 ?A at 1 meas. / 60 s (mode SLOW) approx. 70 ?A at 1 meas. / 1 s (mode FAST) 
 | 
 
 
  
  
 
 | 
Price info
 
   | 
 
 Product-ID: 600161 | 
    
 | 
 
 
  
 | 
 
 
 | 
 
  | 
 | 
 
  | 
   Product Information
   Instruction Manual
   Product Comparison | 
GFTH 200
Hygro-/Thermometer 
Measuring range (temperature): -25.0 ... +70.0 °C Measuring range (humidity): 0.0 ... 100.0 % RH. Resolution: 0.1 % RH. resp. 0.1 °C / 0.1 °F Features: min./max. value memory, hold function, socket for external temperature probe  
 | 
Price info
 
   | 
 
 Product-ID: 600249 | 
    
 | 
 
 
  
 | 
 
 
 | 
 
  | 
   Product Information
   Instruction Manual
   Product Comparison | 
GMH 3330
Precision humidity/flow/temperature measuring device 
Measuring range (humidity): 0.0...100 %RH. Measuring range (temperature): -40...120 °C Measuring range (flow): depending on STS probe Probe: no probe included, please order separately Probe connection: NiCr-Ni flat-pin plug (type K) Miscellaneous: serial interface, ready for bus operation, min./max. value memory, hold function, battery/mains powered calculation of dew point, dew point distance and enthalpy Accessories: (Auszug):TFS 0100 E - Humidity-/Temperature Measuring Probe GOF 130VE - Temperature probe for surfaces GTF 300 - Quick response wire-probe (also for measuring on surfaces)  
 | 
Price info
 
   | 
 
 Product-ID: 600343 | 
 | 
 
 
  
 | 
 
 
 | 
 
  | 
   Product Information
   Instruction Manual | 
TFS 0100 E
Humidity- and Temperature Probe 
Measuring range (humidity): 0.0...100.0 %RH (rec. range of application: 11...90 %RH) Measuring range (temperature): 0.0...60.0 °C Connection cable: length 1m, PVC cable Features: probe calibrated and exchangeable Field of application: all devices of the GMH 3330 and GMH 3350 series  
 | 
Price info
 
   | 
 
 Product-ID: 601488 | 
    
 | 
 
 
  
 | 
 
 
 | 
 
  | 
   Product Information
   Instruction Manual
   Product Comparison | 
GMH 3350
Precision humidity / temperature / flow meter with data logger and alarm 
Measuring Ranges:   Humidity:   0,0 ... 100,0 % r.h. Ambient Temperature:   -40 ... +120 °C Surface Temperature:   -80,0 ... +250,0 °C Dew Point Temperature:   -40,0 ... +70,0 °C Dew Point Distance:   -200,0 ... +290,0 °C Enthalpy:   0 ... 250 kJ/kg Flow Rate:   depending on STS probe Accuracy (only device): Rel. Humidity:    ± 0,1% Ambient Temperature (Pt1000):   ± 0,2% Surface Temperature (NiCr-Ni):   ± 0,5% of reading ± 0,5 °C Flow Rate:   ± 0,1% Measured Data Storage:  99 (manual), 5400 (cyclic) Cycle Time:   1sec. ... 1h Alarm:   visual and acustical via integrated buzzer Miscellaneous:       Serial Interface, Ready for Bus Operation, Min./Max. Value Memory,                                     Hold Function, Real-Time Clock, Battery-/Mains operation Suitable Probes:   TFS 0100 E, STS 005, STS 020, all temperature probes type K with plug                                  ( no probe included, please order separately )  
 | 
Price info
 
   | 
 
 Product-ID: 600345 | 
    
 | 
 
 
  
 | 
 
 
 | 
 
  | 
 | 
 
  | 
 | 
 
 
 |