Weight |
12.4 kg |
Motor size |
110 |
Size |
500 mm |
Rotor surface |
Painted black |
Terminal box material |
PP plastic |
Blade material |
Press-fitted sheet steel blank, sprayed with PP plastic |
Guard grille material |
Steel, coated with black plastic (RAL 9005) |
Number of blades |
5 |
Airflow direction |
V |
Direction of rotation |
Counterclockwise, viewed toward rotor |
Degree of protection |
IP54 |
Insulation class |
"F" |
Ambient temperature note |
Occasional start-up at temperatures between -40°C and -25°C is permitted. For continuous operation at ambient temperatures below -25°C (such as refrigeration applications), use must be made of a fan design with special low-temperature bearings. |
Moisture (F) / Environmental (H) protection class |
H2 |
Max. permitted ambient temp. for motor (transport/storage) |
+80 °C |
Min. permitted ambient temp. for motor (transport/storage) |
-40 °C |
Installation position |
Shaft horizontal or rotor on bottom; rotor on top on request |
Condensation drainage holes |
On rotor side |
Mode |
S1 |
Motor bearing |
Ball bearing |
Touch current according to IEC 60990 (measuring circuit Fig. 4, TN system) |
<= 3,5 mA |
Electrical hookup |
Terminal box |
Motor protection |
Thermal overload protector (TOP) with basic insulation |
with cable |
Axial |
Protection class |
I (with customer connection of protective earth) |
Conformity with standards |
EN 60034-1 (2010) / CE |
Approval |
EAC / CCC / VDE |