- Accuracy: +/- 1.0% of reading plus +/- 0.5% of full scale
- Repeatability: +/- 0.2% of full scale
- Measure all inert gases and all non-condensing clean gases
- Flammable gases: methane, propane, hydrogen, digester gas, natural gas
- Corrosive gases compatible with 316L stainless steel
- 100:1 Turndown
- Gas Temperature -40°F (-40°C) to 350°F (200°C)
- High temperature (HT) option to 750°F (400°C)
- Ambient Temperature -40° F to 120° F (-40° C to 50° C)
- Response time is one second to achieve 63% of final value
- Power supply 18 to 30 VDC (regulated), 625 mA maximum; 100 to 240 VAC, 50/60 Hz, 15 watts maximum
View All Specs
|
- 316 stainless steel construction
- Output Signals: RS-232, 0 to 5 VDC, 0 to 10 VDC, 4 to 20 mA
- User definable pulse output for totalized flow
- Digital communications: Foundation Fieldbus, HART, Modbus RTU, and Profibus DP
- Hazardous-Area Location Enclosure (IP66) and NEMA 4X (IP65)
- Approvals:
- FM (USA) Class I, Div I, Groups B,C,D
- CSA and CRN (Canada)
- ATEX
- CE
- PED (EU)
- GOST R (Russian Federation)
- Chinese Pattern Approval (China
|