GTR 196 | Ados Vietnam

GTR 196 Gas Transmitter
Nhà sản xuất: ADOS Vietnam
0

GTR 196

Gas Transmitter
GTR 196

Application

The gas transmitter ADOS GTR 196 is suitable for continuous measurement of gases in normal areas and areas where there is a risk of explosion.

By employing 6 different types of sensor, noxious, explosive and non-combustible gases and vapours can be measured.

A current signal is generated that is proportional to the measured concentration of gas, which is transmitted to an evaluation unit placed in a safe area, away from any dangers of explosion.

The type test of the explosion-protected gas transmitter, is completed by the KEMA.

Test certificate: KEMA 03 ATEX 2403 X
Degree of protection: II 2 G, Ex demb [ia] IIC T6

 

Fields of Application

  • Chemical industry
  • Manufacture of paints and varnishes
  • Plastics processing plants
  • Sewage works
  • Gas-fired boiler systems
  • Liquid gas storage houses
  • Laboratories
  • Oxygen concentration measurements
  • Refineries
  • Cold storage houses (Ammonia monitoring)
  • Paint spraying booths
  • ... and many more.
 

TGS sensor

The TGS sensor contains a semiconductor sensor, which is constructed on SnO2-sintered N-substrate. When combustible or reducing gases are absorbed by the surface of the sensor, the concentration of the test gas is determined by the change in conductivity.

1 = Circuit voltage 
2 = Heating voltage
3 = Load resistor

 

VQ sensor

The head of the VQ sensor functions on the principle of heat reaction. When combustible or reducing gases or vapours come in contact with the measuring element, they are subjected to catalytic combustion, which causes a rise in temperature; this rise causes a change in the resistance of the measuring element which is used as a measure of the component of gas being tested. 

The inert element is for compensating the temperature and conductivity of the test gas.

1 = Catalyzer pellistor
2 = Electric connections
3 = Inert pellistor
4 = Diffusion filter

 

GOW sensor

The GOW sensor functions on the principle of thermal conductivity. Two rhenium-tungsten resistors are used as a measuring element, where the comparison element is subjected to normal ambient air and the measuring element is subjected to the test gas. Any change in the concentration of gas at the measurement element causes a change in temperature, which is due to the variation of conductivity.

The resultant change in resistance is a direct measure of the gas concentration.

 

1 = Disffusion filter 
2 = Test resistor
3 = Comparison resistor

 

TOX sensor

The TOX sensor is a measurement system with an electro-chemical cell, where the sampled gas is measured by diffusion. In the case of oxygen measurement the oxygen content is reduced in an electrolyte, thus producing a small flow of current (electro-chemical process). At a constant air pressure, this current is directly proportional to the oxygen concentration in the sampled air.

1 = Anode
2 = Electrolyte
3 = Cathode
4 = Diffusion path
5 = Diffusion filter 
6 = Test gas

 

 

The IR sensor

The test gas flows through a measurement chamber that incorporates an IR radiating source and a two-channel infrared detector. The intensity of the infrared radiation is reduced as it passes through the gas molecules. The concentration of the gas can then be calculated by the magnitude of the reduction in intensity. Since only absorption of the wavelength (A) specific to the gas under test in relation to the wavelength (B) not absorbed by a test gas is considered, interference due to dust, ageing etc., is almost fully compensated.

1 = Infrared-radiation source
2 = Test gas
3 = Diffusion filter
4 = Infrared-detector
5 = Measurement chamber

 

Technical data

TypeTGSVQGOW
Measurement method Semiconductor Heat reduction Thermal conductivity
Measurement range ppm ranges to 
100 % LEL
ppm ranges to 
100 % LEL
from 0-5 Vol % 
to 0-100 Vol %
Percentage error of f.s.d. ±5 % ±3 % ±5 %
Temperature range -20 °C to +45 °C -20 °C to +45 °C -20 °C to +45 °C
Temperature effect 3 % 2 % 3 %
Response time (t90) approx. 60 sec. approx. 40 sec. approx. 60 sec.
Pressure effect (atm.) 1 % 1 % 1 %
Mounting position optional ± 90° from the vertical mounting position optional ± 90° from the vertical mounting position optional ± 90° from the vertical mounting position
Application Poisonous, combustible and explosive gases in the LEL region Poisonous, combustible and explosive gases in the LEL region Gases exhibiting substantial differences in thermal conductivity, compared to air
Versions available industrial (Al), industrial (VA)- and Ex-version industrial (Al), industrial (VA)- and Ex-version industrial (Al), industrial (VA)- and Ex-version
Service life of the sensor unlimited, when used for gases not causing catalytic poisoning unlimited, when used for gases not causing catalytic poisoning unlimited, when used with gases that do not attack aluminium, rhenium-tungsten or gold
Supply voltage 15 – 30 V 15 – 30 V 15 – 30 V
Interfaces 3-wire techniques 4-20 mA or LON© 4-wire techniques, galvanically isolated, data transfer 78 kB/s 3-wire techniques 4-20 mA or LON© 4-wire techniques, galvanically isolated, data transfer 78 kB/s 3-wire techniques 4-20 mA or LON© 4-wire techniques, galvanically isolated, data transfer 78 kB/s
Protection

Ex-Version
II 2 G
Ex demb [ia] IIC T6
KEMA 03 
ATEX 2403 X
II 2 G
Ex demb [ia] IIC T6 
KEMA 03 
ATEX 2403 X
II 2 G
Ex demb [ia] IIC T6 
KEMA 03 
ATEX 2403 X
Protection class IP 54 IP 54 IP 54
Dimensions 
(W x H x D)
150 x 170 x 105 mm 150 x 170 x 105 mm 150 x 170 x 105 mm
Weight 2,7 kg 2,7 kg 2,7 kg

 

TypeTOXIRPID
Measurement method Electro-chemical cell Infrared Photo-Ionisation
Measurement range ppm ranges to 
100 LEL %
0–100 % LEL CH4, C3H8, C2H2,
0–100 Vol % CH4
0–1, 2, 3, 4, 5 Vol % CO2
0 – 200 ppm to
0 – 2.000 ppm
Percentage error of f.s.d. ± 3% ± 2 % ± 5 %
Temperature range -20 °C to +45 °C -20 °C to +45 °C -20 °C to +45 °C
Temperature effect 2 % 2 % 3 %
Response time (t90) approx. 60 sec. approx. 45 sec. approx. 120 sec.
Pressure effect (atm.) 1 % 4 % 1 %
Mounting position optional ± 90° from the vertical mounting position optional ± 90° from the vertical mounting position optional ± 90° from the vertical mounting position
Application O2, CO, NH3, NO2,
SO2, H2S a.o.
CH4 (Vol %; LEL)
Propane (LEL)
CO2 (Vol %)
e.g. C7H8, C8H10
CHCl3, PH3
Versions available industrial (Al),
industrial (VA)-
and Ex-version
industrial (Al),
industrial (VA)-
and Ex-version
industrial (Al),
industrial (VA)-
and Ex-version
Service life of the sensor 12 months to 5 years depending on the measuring cell approx. 5 years 12 monthss
Supply voltage 15 – 30 V 15 – 30 V 15 – 30 V
Interfaces 3-wire techniques 4-20 mA or LON© 4-wire techniques, galvanically isolated, data transfer 78 kB/s 3-wire techniques 4-20 mA or LON© 4-wire techniques, galvanically isolated, data transfer 78 kB/s 3-wire techniques 4-20 mA or LON© 4-wire techniques, galvanically isolated, data transfer 78 kB/s
Protection

Ex-Version
II 2 G
Ex demb [ia] IIC T6
KEMA 03 
ATEX 2403 X
II 2 G
Ex demb [ia] IIC T6
KEMA 03
ATEX 2403 X
II 2 G
Ex demb [ia] IIC T6
KEMA 03
ATEX 2403 X
Protection class IP 54 IP 54 IP 54
Dimensions (WxHxD)

100 x 180 x 80 mm

100 x 180 x 80 mm

100 x 180 x 80 mm

Weight 1,1 kg 1,1 kg 1,1 kg