10L1Z-UEGA1AA0A5AA

10L1Z-UEGA1AA0A5AA
Nhà sản xuất: Endress Hauser
0

Measuring PrincipleElectromagneticProduct headlineThe flowmeter with a weight‐optimized sensor and highly cost‐effectiveness. Fully suitable for standard applications in the water and wastewater industry.
Sensor featuresReduced installation costs – flexible mounting by one‐of‐a‐kind lap‐joint flange concept (DN <350/14"). Energy‐saving flow measurement – no pressure loss due to cross‐section constriction. Maintenance‐free – no moving parts. Up to 30 % less sensor weight. Nominal diameter: DN 25 to 2400 (1 to 90").
Transmitter featuresCost‐effective – designed for easy applications and direct integration. Safe operation – display provides easy readable process information. Fully industry compliant – IEC/EN/NAMUR. 2‐line display with push buttons. Device in compact or remote version.
Nominal diameter rangeLap joint flange; lap joint flange, stamped plate: DN 25 to 300 (1 to 12") 
Fixed flange: DN 350 to 2400 (14 to 90")
Wetted materialsLiner: PTFE; Polyurethane; Hard rubber 
Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022)
Measured variablesVolume flow
Max. measured errorVolume flow: ±0.5 % o.r. ± 2 mm/s (±0.5 % o.r. ± 0.08 in/s)
Measuring range9 dm³/min to 162 000 m³/h (2.5 gal/min to 1030 Mgal/d)
Max. process pressurePN 16, Class 150
Medium temperature rangeLiner material hard rubber: 0 to +80 °C (+32 to +176 °F) 
Liner material polyurethane: –20 to +50 °C (–4 to +122 °F) 
Liner material PTFE: –20 to +90 °C (–4 to +194 °F)
Ambient temperature rangeFlange material carbon steel: –10 to +60 °C (+14 to +140 °F) 
Flange material stainless steel: –40 to +60 °C (–40 to +140 °F)
Sensor housing materialDN 25 to 300 (1 to 12"): AlSi10Mg, coated 
DN 350 to 2400 (14 to 90"): Carbon steel with protective varnish 
Sensor connection housing: AlSi10Mg, coated
Transmitter housing materialPowder‐coated die‐cast aluminum
Degree of protectionCompact version: IP66/67, type 4X enclosure 
Sensor remote version (standard): IP66/67, type 4X enclosure 
Sensor remote version (option): IP68, type 6P enclosure 
Transmitter remote version: IP67, type 4X enclosure
Display/Operation2-line display with push buttons 
Configuration via local display and operating tools possible
Outputs4‐20 mA HART (active)
Pulse/switch output (passive)
InputsNone
Digital communicationHART
Power supplyDC 11 to 40 V 
AC 85 to 250 V (45 to 65 Hz) 
AC 20 to 28 V (45 to 65 Hz) 

Hazardous area approvalscCSAus
Other approvals and certificatesCalibration performed on accredited calibration facilities (acc. to ISO/IEC 17025) 
Drinking water approval: ACS, KTW/W270, NSF 61, WRAS BS 6920