Mechanical data |
|
Design of electrical connection |
Screw connection |
Cable section |
- Min. Cable section |
0,25 mm² |
- Max. Cable section |
1.5 mm² |
AWG-Number |
23 - 15 |
Mechanical life |
≥ 1.000.000 operations |
notice |
All indications about the cable section are including the conductor ferrules. |
restistance to shock |
30 g / 11 ms |
Resistance to vibration |
10 ... 55 Hz, Amplitude 1 mm |
Emergency unlocking device (Y/N) |
No |
Manual release (Y/N) |
Yes |
Emergency release (Y/N) |
No |
Latching force |
30 N |
Clamping force F |
2000 N |
Max. Actuating speed |
≤ 0,2 m/s |
|
Ambient conditions |
|
Ambient temperature |
- Min. environmental temperature |
−25 °C |
- Max. environmental temperature |
+50 °C |
Storage and transport temperature |
- Min. Storage and transport temperature |
−25 °C |
- Max. Storage and transport temperature |
+85 °C |
Relative humidity |
30% ... 95% |
- non-condensing |
Protection class |
IP67 to IEC/EN 60529 |
Air clearances and creepage distances To IEC/EN 60664-1 |
- Rated impulse withstand voltage Uimp |
0,8 kV |
- Overvoltage category |
III |
- Degree of pollution |
3 |
|
Electrical data |
|
Number of auxiliary contacts |
0 piece |
Number of safety contacts |
2 piece |
Cross circuit/short circuit recognition possible (Y/N) |
Yes |
Power to unlock |
No |
Power to lock |
Yes |
Supply voltage UB |
- Min. supply voltage |
20.4 VDC |
- Max. supply voltage |
26.4 VDC |
Switch frequency |
1 Hz |
Rated insulation voltage Ui |
32 VDC |
Operating current Ie |
1.2 A |
Utilisation category |
DC-12, DC-13 |
No-load current I0 |
0,6 A |
Device insulation |
≤ 4 A if used in accordance with UL 508 |
|
Electrical data - Safety inputs |
|
Safety inputs |
X1 and X2 |
Rated operating voltage Ue |
- 3 V ... 5 V (Low) 15 V ... 30 V (High) |
Operating current Ie |
> 2 mA / 24 V |
|
Electrical data - Safety outputs |
|
Safety outputs |
Y1 and Y2 |
Fuse rating |
short-circuit proof, p-type |
Rated operating voltage |
0 V ... 4 V under Supply voltage UB |
Residual current Ir |
≤ 0,5 mA |
Operating current Ie |
0,25 A |
Utilisation category |
DC-12, DC-13 |
|
Electrical data - Diagnostic output |
|
Serial diagnostics (Y/N) |
No |
Fuse rating |
p-type, short-circuit proof |
Operating current Ie |
0,05 A |
Utilisation category |
DC-12, DC-13 |
Wiring capacitance for serial diagnostics |
- |
diagnostic signals |
guard door closed |
Operating principle of the diagnostic output |
The short-circuit proof diagnostic output OUT can be used for central visualisation or control tasks, e.g. in a PLC. |
notice |
The diagnostic output is not a safety-relevant output! |
|
Electrical data - Solenoid control IN |
|
Rated operating voltage Ue |
- 3 V ... 5 V (Low) 15 V ... 30 V (High) |
Operating current Ie |
typically 10 mA / 24 V, dynamically 20 mA |
|
LED switching conditions display |
|
LED switching conditions display (Y/N) |
Yes |
LED switching conditions display |
- Supply voltage UB |
green LED |
- switching condition |
yellow LED |
- Error functional defect |
red LED |
|
ATEX |
|
Explosion protection categories for gases |
None |
Explosion protected category for dusts |
None |
|
Dimensions |
|
Dimensions of the sensor |
- Width of sensor |
40 mm |
- Height of sensor |
220 mm |
- Length of sensor |
50 mm |
|
notice |
|
As lons as the actuating unit remains inserted in the solenoid interlock, the unlocked safety guard can be relocked. The safety outputs then will be enabled again; opening the safety guard therefore is not required. |
|