Mechanical data |
|
Design of electrical connection |
Screw connection |
Conductor with strain relief |
No |
Cable section |
- Min. Cable section |
- Max. Cable section |
1 x 1.5 mm² |
mechanical installation conditions |
flush |
Switch distance |
5 mm |
Reduction factor 1 met (Y/N) |
No |
Protection circuit |
inductive interference protection, Protection against polarity reversal |
Pressure resistant (Y/N) |
No |
Tightening torque for nuts |
A/F 24 max. 1800 Ncm |
|
Ambient conditions |
|
Ambient temperature |
- Min. environmental temperature |
−25 °C |
- Max. environmental temperature |
+70 °C |
Protection class |
IP67 to IEC/EN 60529 |
|
Electrical data |
|
Design of control element |
Normally open contact (NO) or Opener (NC) |
Number of wire |
3 piece |
Voltage type |
DC, direct current |
Supply voltage UB |
- Min. supply voltage |
10 V |
- Max. supply voltage |
60 V |
Switch frequency |
approx. 500 Hz |
Voltage drop Ud |
approx. 1.5 V (400 mA) |
Operating current Ie |
400 mA |
No-load current I0 |
approx. 5.5 mA (24 V) |
|
Outputs |
|
Design of control output |
PNP |
|
LED switching conditions display |
|
LED switching conditions display (Y/N) |
Yes |
- yellow LED |
|
ATEX |
|
Explosion protection categories for gases |
None |
Explosion protected category for dusts |
None |
|
Dimensions |
|
Dimensions of the sensor |
- Length of sensor |
126 mm |
- Diameter of sensor |
M18 |
|
notice |
|
Instead of nuts, a mounting clamp can be provided. |
Programmable by repositioning the plug-in jumper at the terminal screws |
|