Models
- 2100 flow tube length 100 mm
- 2150 flow tube length 150 mm
- 2300 flow tube length 300 mm
- 2340 flow tube length 300 mm
Technical specifications:
Measuring ranges:
- 0,1 l/h ... 1000 l/h H2O
- 1Nl/h ... 30 Nm3/h air
Accuracy:
- 2100 model ±3,5% f.s.
- 2150 model ±3% f.s.
- 2300/2340 models ±1,6% f.s.
Connections:
- 2100/2150/2300 models 1/4” BSP, NPT
- 2340 model 1/2” or 3/4” M BSP, NPT
Materials:
- Flow tube: borosilicate glass
- Wetted parts: EN 1.4404 (SS 316L)
- Float: EN 1.4404 (SS 316L), glass, plastic, ceramic
Local indication
Options:
- 1 or 2 adjustable switches (optical detector, inductive sensor or reed switch)
- Constant flow regulator RCD or RCA
- Without valve