| Mechanical data |
| |
| Design of electrical connection |
Screw connection |
| Cable section |
| - Min. Cable section |
0,25 mm² |
| - Max. Cable section |
1.5 mm² |
| AWG-Number |
23 - 15 |
| Mechanical life |
≥ 1.000.000 operations |
| notice |
All indications about the cable section are including the conductor ferrules. |
| restistance to shock |
30 g / 11 ms |
| Resistance to vibration |
10 ... 55 Hz, Amplitude 1 mm |
| Emergency unlocking device (Y/N) |
No |
| Manual release (Y/N) |
Yes |
| Emergency release (Y/N) |
No |
| Latching force |
30 N |
| Clamping force F |
2000 N |
| Max. Actuating speed |
≤ 0,2 m/s |
| |
| Ambient conditions |
| |
| Ambient temperature |
| - Min. environmental temperature |
−25 °C |
| - Max. environmental temperature |
+50 °C |
| Storage and transport temperature |
| - Min. Storage and transport temperature |
−25 °C |
| - Max. Storage and transport temperature |
+85 °C |
| Relative humidity |
30% ... 95% |
| - non-condensing |
| Protection class |
IP67 to IEC/EN 60529 |
| Air clearances and creepage distances To IEC/EN 60664-1 |
| - Rated impulse withstand voltage Uimp |
0,8 kV |
| - Overvoltage category |
III |
| - Degree of pollution |
3 |
| |
| Electrical data |
| |
| Number of auxiliary contacts |
0 piece |
| Number of safety contacts |
2 piece |
| Cross circuit/short circuit recognition possible (Y/N) |
Yes |
| Power to unlock |
No |
| Power to lock |
Yes |
| Supply voltage UB |
| - Min. supply voltage |
20.4 VDC |
| - Max. supply voltage |
26.4 VDC |
| Switch frequency |
1 Hz |
| Rated insulation voltage Ui |
32 VDC |
| Operating current Ie |
1.2 A |
| Utilisation category |
DC-12, DC-13 |
| No-load current I0 |
0,6 A |
| Device insulation |
≤ 4 A if used in accordance with UL 508 |
| |
| Electrical data - Safety inputs |
| |
| Safety inputs |
X1 and X2 |
| Rated operating voltage Ue |
- 3 V ... 5 V (Low) 15 V ... 30 V (High) |
| Operating current Ie |
> 2 mA / 24 V |
| |
| Electrical data - Safety outputs |
| |
| Safety outputs |
Y1 and Y2 |
| Fuse rating |
short-circuit proof, p-type |
| Rated operating voltage |
0 V ... 4 V under Supply voltage UB |
| Residual current Ir |
≤ 0,5 mA |
| Operating current Ie |
0,25 A |
| Utilisation category |
DC-12, DC-13 |
| |
| Electrical data - Diagnostic output |
| |
| Serial diagnostics (Y/N) |
No |
| Fuse rating |
p-type, short-circuit proof |
| Operating current Ie |
0,05 A |
| Utilisation category |
DC-12, DC-13 |
| Wiring capacitance for serial diagnostics |
- |
| diagnostic signals |
guard door closed |
| Operating principle of the diagnostic output |
The short-circuit proof diagnostic output OUT can be used for central visualisation or control tasks, e.g. in a PLC. |
| notice |
The diagnostic output is not a safety-relevant output! |
| |
| Electrical data - Solenoid control IN |
| |
| Rated operating voltage Ue |
- 3 V ... 5 V (Low) 15 V ... 30 V (High) |
| Operating current Ie |
typically 10 mA / 24 V, dynamically 20 mA |
| |
| LED switching conditions display |
| |
| LED switching conditions display (Y/N) |
Yes |
| LED switching conditions display |
| - Supply voltage UB |
green LED |
| - switching condition |
yellow LED |
| - Error functional defect |
red LED |
| |
| ATEX |
| |
| Explosion protection categories for gases |
None |
| Explosion protected category for dusts |
None |
| |
| Dimensions |
| |
| Dimensions of the sensor |
| - Width of sensor |
40 mm |
| - Height of sensor |
220 mm |
| - Length of sensor |
50 mm |
| |
| notice |
| |
| As lons as the actuating unit remains inserted in the solenoid interlock, the unlocked safety guard can be relocked. The safety outputs then will be enabled again; opening the safety guard therefore is not required. |
| |